An invited survey of the theory of hybrid automata, the standard model for a digital controller driving an analogue plant. Control modes are graph vertices, each with a flow condition (a differential equation or inclusion) and an invariant; control switches are edges with jump conditions that reset continuous variables. Henzinger collects which verification questions can be decided for which subclasses, and how symbolic state-space computation works when the state space is uncountable.

Where decidability stops for hybrid automata

  1. Modes are vertices with flow conditions and invariants. Switches are edges with jump conditions that reset variables.

  2. Each derivative ranges over a fixed interval. Emptiness is in PSPACE and time-abstract trace inclusion is decidable in EXPSPACE.

  3. Reachability becomes undecidable if flow bounds change with the mode, different variables are related, or a single stopwatch is added to clocks.

  4. Symbolic reachability with linear predicates is still possible, as a procedure that may not terminate.

Findings

  • The running example is a thermostat: in mode Off the temperature follows x’ = -0.1x, in mode On x’ = 5 − 0.1x, starting at 20 degrees, with switches guarded by thresholds such as x < 19.
  • Rectangular automata (each derivative ranges over a fixed interval that does not change with the mode, and variables are decoupled) are the decidability frontier. A drifting clock fits: its rate lies in [1 − ε, 1 + ε]. Their time-abstract traces are regular, emptiness is in PSPACE and time-abstract trace inclusion is decidable in EXPSPACE.
  • Step past that line and reachability becomes undecidable: letting flow bounds change with the mode, relating different variables, or adding a single stopwatch to clocks is enough.
  • For linear hybrid automata, symbolic reachability with linear predicates is still possible, as a procedure that may not terminate.

Limits

  • Exact verification works for very simple dynamics. A quadrotor or a vessel in waves is far outside the decidable classes, so practice relies on over-approximation and reachability tools.
  • A theory survey with no case study of a real controller. I read the 1996 Berkeley technical report version, which matches the LICS paper.

Relevance

Every claim that a robot controller “provably stays safe” rests on a hybrid model like this one, and the undecidability results explain why most robot safety arguments end up as runtime checks instead (Simplex, SOTER). It follows timed automata; see safe control and runtime monitoring.